Uploaded image for project: 'hc2vpp'
  1. hc2vpp
  2. HC2VPP-202

routing: unable to read multi-path operational data

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Done
    • Icon: Medium Medium
    • 17.10
    • 17.10
    • None
    • Honeycomb: 1.17.10-3117

      VPP: {

      "version": "17.10-rc0~86-g7d4a22c~b2618",
      "build_date": "Tue Jul 25 14:32:10 UTC 2017",
      }

      When I configure a multipath route according to the postman (included) and I GET operational data for the route, the response is code 500 error, and the log shows:

      ReadFailedException: Failed to read...static.routes.ipv4.Route[key=RouteKey [_id=0]]

      ...

      IllegalStateException: Unexpected size of list: []. Single item expected.

       

      Notes:

      Also affects IPv6 multipath in the same way.

      Does not happen on 17.07.

      Likely caused by a VPP change between 13th and 21st July in 17.10

            jsrnicek_cisco Jan Srnicek
            selias Samuel Eliáš
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: